J. H. Preston; N. E. Sweeting; F. H. Burstall
(H. M. Stationery Office, 1945)
The smoke filament technique for detecting transition points is limited to speeds below 180 ft./sec, for orthodox atmospheric tunnels with good lighting and viewing conditions. Also many tunnels are of the enclosed pressure ...